Achieve reliable epoxy resin curing with Diethylenetriamine Deta 99% Purity, a colorless curing agent that ensures consistent performance for industrial applications. Its high purity (99% min) minimizes impurities that could compromise bond strength, making it ideal for precision-critical projects.
- CAS 111-40-0 certified, meeting ISO standards for quality and safety in chemical processing
- Molecular formula C4H13N3 ensures optimal reactivity with epoxy resins, reducing curing time while enhancing durability
- Available in plastic or steel drum packaging options to suit your storage and transportation needs, sourced from trusted Jiangsu suppliers
Description
For industrial manufacturing and laboratory research purposes only.
Product Specifications
| Parameter | Value |
|---|---|
| Model NO. | Deta |
| Certification | ISO |
| CAS No. | 111-40-0 |
| Einecs | 203-865-4 |
| Molecular Formula | C4h13n3 |
| Purity | 99% Min |
| Color | Colorless |
| Transport Package | Plastic Drum/Steel Drum |
| Origin | Jiangsu, China |
Diethylenetriamine (DETA) CAS 111-40-0: Overcoming Epoxy Curing Agent Challenges in Industrial Production
For over a decade in the chemical supply industry, we’ve witnessed how inconsistent Diethylenetriamine quality disrupts epoxy resin productionโimpure batches causing unpredictable curing times, color variations ruining finished products, and supply delays halting manufacturing lines. Research institutions too face frustrations when reagent purity fluctuations compromise experimental reproducibility.
Stabilizing Epoxy Curing Processes with High-Purity DETA
Our Diethylenetriamine Deta 99% Purity directly addresses these pain points through rigorous manufacturing control. As a trusted supplier serving 50+ countries, we ensure each batch maintains consistent 99% minimum purity, eliminating the variability that plagues industrial curing operations and laboratory research.
Key Industrial Applications of DETA CAS 111-40-0
Diethylenetriamine CAS 111-40-0 primarily functions as an epoxy resin curing agent in composite manufacturing, adhesives production, and coatings formulation. Its amine groups enable cross-linking reactions that impart mechanical strength and chemical resistance to cured epoxy systems. This colorless curing agent is also utilized in the synthesis of chelating agents and corrosion inhibitors for industrial processes.
Critical Specifications for Reliable Epoxy Curing
The 99% minimum purity of our DETA ensures minimal impurities that could interfere with curing reactions or introduce discoloration. Its colorless appearance guarantees aesthetic consistency in clear epoxy formulations. The precise molecular structure (C4h13n3) ensures predictable stoichiometric reactions, while strict ISO certification standards validate our production processes. These specifications collectively prevent curing defects, reduce waste, and ensure batch-to-batch reproducibility.
Benefits of Our High Purity Deta Curing Agent
Using our High Purity Deta Curing Agent translates to tangible production benefits: reduced scrap rates from consistent curing, lower rework costs due to predictable performance, and compliance with stringent industrial quality standards. Unlike low-purity alternatives that risk resin brittleness or incomplete curing, our ISO-certified DETA delivers reliable cross-linking efficiency, ultimately lowering long-term production costs through process stability.
Our Quality Assurance Commitment
Every DETA batch undergoes comprehensive testing including HPLC purity analysis and FTIR spectroscopy to verify chemical identity. We provide detailed COA documents with each shipment, specifying key parameters like moisture content and amine value. Our production facility maintains 500MT monthly capacity to ensure stable supply, while our 30-day quality guarantee allows for returns if specifications aren’t met. Dedicated technical support staff are available to address application-specific questions.
Certificate of Analysis & Documentation
Each delivery includes a batch-specific Certificate of Analysis with test results for purity, appearance, and key impurities. Material Safety Data Sheets (MSDS) containing handling precautions and regulatory information are provided as standard. For critical applications, we can arrange additional third-party testing at accredited laboratories upon request.
Storage & Handling
- Store in a cool, dry, well-ventilated area, sealed and away from direct sunlight.
- Keep away from incompatible materials, food and feed sources.
- Handle with appropriate personal protective equipment (gloves, goggles, lab coat).
- Follow good industrial hygiene practices. Avoid inhalation and skin contact.
- Refer to MSDS for detailed storage and safety instructions.
Streamlined Procurement Process
Initiate your order by submitting an inquiry through our platform with your required quantity and delivery timeline. We’ll provide a formal quotation including technical specifications within 24 hours. For first-time users, sample quantities are available for qualification testing. Once specifications are confirmed, bulk orders typically ship within 5-7 business days with full documentation package included.
Frequently Asked Questions
Q: What is the shelf life of your DETA product?
A: When stored properly in sealed containers, our Diethylenetriamine maintains specification for 12 months from the manufacturing date.
Q: Is this product suitable for pharmaceutical or food applications?
A: No, this product is supplied exclusively FOR INDUSTRIAL AND LABORATORY RESEARCH USE ONLY. It is not intended for direct human consumption or pharmaceutical applications.
Q: What documentation accompanies each shipment?
A: Every order includes a Certificate of Analysis (COA), Material Safety Data Sheet (MSDS), and shipping documents. Additional regulatory certificates can be provided upon request.
Q: Can you accommodate custom packaging requirements?
A: Yes, we offer flexible packaging options including 25kg plastic drums and 200kg steel drums. Special packaging can be arranged for large-volume orders.
Q: How is the purity of your DETA verified?
A: Purity is determined using high-performance liquid chromatography (HPLC) analysis, with results documented in each batch’s COA. We can provide chromatograms for review upon request.