Enhance water treatment efficiency with our High Purity DETA Diethylenetriamine 99% Min CAS 111-40-0, a reliable solution that ensures consistent performance for industrial applications. Sourced from Jiangsu, China and certified by ISO, this colorless compound with the molecular formula C4h13n3 delivers the purity your processes demand.
- 99% minimum purity guarantees minimal impurities, reducing the risk of unexpected reactions in water treatment systems
- Packaged in secure Plastic Drum/Steel Drum containers to maintain integrity during transport and storage
- Complies with industry standards, supporting seamless integration into existing supply chains for reliable procurement
Description
For industrial manufacturing and laboratory research purposes only.
Product Specifications
| Parameter | Value |
|---|---|
| Model NO. | Deta |
| Certification | ISO |
| CAS No. | 111-40-0 |
| Einecs | 203-865-4 |
| Molecular Formula | C4h13n3 |
| Purity | 99% Min |
| Color | Colorless |
| Transport Package | Plastic Drum/Steel Drum |
| Origin | Jiangsu, China |
Addressing Water Treatment Challenges with High Purity DETA (CAS 111-40-0)
Industrial water treatment processes often face critical hurdles from inconsistent chemical quality—fluctuating DETA purity levels can lead to inefficient chelation, unexpected byproducts in wastewater treatment, and failed compliance with environmental standards. Research teams similarly struggle with batch-to-batch variations that compromise experimental reproducibility, while procurement delays due to unstable supply chains frequently disrupt production schedules. In our 10+ years serving chemical professionals, these are the recurring pain points we’ve helped resolve through precision manufacturing.
A Stable and Reliable DETA Supply Solution
Our High Purity DETA (Diethylenetriamine) 99% Min directly addresses these challenges by delivering consistent quality that industrial facilities and research labs depend on. As a supplier with expertise in serving 50+ countries and 10000+ industrial clients, we understand that water treatment applications require chemicals with minimal impurities to ensure optimal performance in chelating metal ions and stabilizing treatment processes. Our strict production controls eliminate the variability that undermines operational efficiency.
Typical Industrial Applications
Diethylenetriamine 99% Min (CAS 111-40-0) plays a vital role in industrial water treatment as a key chelating agent, effectively binding heavy metal ions to prevent scaling and corrosion in cooling systems and boilers. Beyond water treatment, it serves as an intermediate in the synthesis of pharmaceuticals, agrochemicals, and surfactants within controlled industrial environments. Its versatile reactivity also makes it valuable in laboratory research for developing new materials and chemical processes, strictly for non-consumable industrial applications.
Why Key Specifications Matter
The 99% minimum purity of our DETA is critical for minimizing副反应 and impurity interference in water treatment—even small deviations can reduce chelation efficiency and introduce contaminants into treated water. The colorless appearance indicates low levels of oxidation byproducts, ensuring compatibility with sensitive processes. Our ISO certification validates adherence to global quality standards, while tightly controlled molecular composition (C4h13n3) guarantees consistent reactivity. These specifications collectively ensure that each batch performs predictably, whether in large-scale industrial systems or precise laboratory settings.
What You Gain With Our Water Treatment DETA
Choosing our High Purity DETA translates to tangible operational benefits: reduced maintenance costs from improved scaling control, enhanced process stability with consistent chemical performance, and compliance with stringent environmental regulations. In contrast, lower-quality DETA risks equipment damage, failed water treatment cycles, and potential regulatory penalties. Our ISO-certified production process ensures that every drum meets the same high standards, delivering long-term supply stability that eliminates the hidden costs of inconsistent raw materials.
Why You Can Trust Us
Our quality assurance framework includes multi-stage testing using advanced analytical techniques such as HPLC and GC to verify purity and composition. Each batch is accompanied by a detailed Certificate of Analysis (COA) documenting key parameters. We stand behind our product with a no-questions-asked return policy for non-conforming shipments. With dedicated technical support and a production capacity designed for stable supply, we provide the reliability that industrial and research customers require. Our 10+ years in the industry and global client base further validate our commitment to quality.
Certificate of Analysis & Documentation
Every order of our High Purity DETA includes a batch-specific COA and MSDS, providing comprehensive safety and quality data. For critical applications, detailed chromatographic profiles and impurity analysis can be requested to support your internal quality control processes. This documentation ensures full traceability and compliance with industrial safety protocols.
Storage & Handling
- Store in a cool, dry, well-ventilated area, sealed and away from direct sunlight.
- Keep away from incompatible materials, food and feed sources.
- Handle with appropriate personal protective equipment (gloves, goggles, lab coat).
- Follow good industrial hygiene practices. Avoid inhalation and skin contact.
- Refer to MSDS for detailed storage and safety instructions.
How to Place Your Order
Initiate your procurement process by submitting an inquiry through our platform, specifying your required quantity and packaging preferences (plastic drum or steel drum). We can arrange sample delivery for qualification testing prior to full order placement. Once specifications are confirmed, our supply chain team ensures timely delivery with all necessary documentation. Partnering with us means accessing a reliable DETA source backed by technical expertise and quality commitment.
Frequently Asked Questions
Q: What is the shelf life of your High Purity DETA?
A: When stored properly in sealed containers under recommended conditions, our DETA maintains stability for 12 months from the date of manufacture.
Q: Can this product be used in food or pharmaceutical applications?
A: No, this product is strictly for industrial and laboratory research use only, not for direct human consumption or therapeutic applications.
Q: What documentation is provided with each shipment?
A: Every order includes a Certificate of Analysis (COA) and Material Safety Data Sheet (MSDS) specific to the batch.
Q: Do you offer custom packaging options?
A: We currently provide standard packaging in plastic drums or steel drums; please contact our sales team for volume-specific packaging inquiries.
Q: How is the purity of your DETA verified?
A: Purity is confirmed through rigorous testing using HPLC and GC analysis, with results documented in the batch COA.







