For industrial manufacturing and laboratory research purposes only.
Product Specifications
| Parameter | Value |
|---|---|
| Model NO. | Deta |
| Certification | ISO |
| CAS No. | 111-40-0 |
| Einecs | 203-865-4 |
| Molecular Formula | C4h13n3 |
| Purity | 99% Min |
| Color | Colorless |
| Transport Package | Plastic Drum/Steel Drum |
| Origin | Jiangsu, China |
Addressing Critical Challenges in Water Treatment with Diethylenetriamine (CAS 111-40-0)
After a decade of serving water treatment facilities across 50+ countries, we’ve witnessed how inconsistent Diethylenetriamine (DETA) quality disrupts coagulation processes—impurities causing sludge buildup, purity fluctuations leading to over-dosing, and delayed deliveries halting treatment cycles. Research labs repeatedly report failed replications due to unstandardized DETA compositions, wasting both time and resources in critical studies.
A Stable and Reliable Chemical Supply Solution
Our Diethylenetriamine (CAS 111-40-0) with 99% purity directly addresses these challenges. As a 10+ year supplier to 10,000+ industrial clients, we ensure each batch maintains strict purity standards, eliminating the variability that plagues water treatment efficiency and research reproducibility. Our streamlined supply chain guarantees Quick Delivery DETA, minimizing production downtime for both large-scale water treatment plants and laboratory operations.
Typical Industrial Applications
Diethylenetriamine for Water Treatment is widely utilized as a chelating agent and flocculant in industrial water purification processes, effectively removing heavy metal ions and suspended particles. Its amine groups enable strong binding with metal contaminants, making it indispensable in wastewater treatment for industries ranging from petrochemicals to electronics manufacturing. Additionally, it serves as a key intermediate in the synthesis of corrosion inhibitors and ion exchange resins for industrial water systems.
Why Key Specifications Matter
The 99% minimum purity of our DETA ensures minimal interference from organic impurities, which is critical for maintaining consistent reaction kinetics in water treatment formulations. A colorless appearance indicates low oxidation by-products, preventing discoloration in treated water streams. The ISO certification validates our adherence to global quality management standards, while the molecular formula C4h13n3 confirms the structural integrity necessary for effective chelation. Rigorous control of these parameters guarantees that our DETA performs predictably across diverse industrial applications, from municipal water treatment to specialized research protocols.
What You Gain With Our Product
Choosing our DETA 99% Purity means avoiding the hidden costs of substandard chemicals: reduced equipment maintenance from minimized sludge formation, lower reagent consumption due to consistent reactivity, and compliance with strict environmental regulations through controlled impurity levels. Unlike unreliable suppliers, our ISO-certified production ensures batch-to-batch uniformity, protecting your processes from unexpected failures. The long-term value lies in stabilized operations—whether you’re scaling water treatment capacity or conducting sensitive material science research.
Why You Can Trust Us
Our commitment to quality is backed by comprehensive testing protocols: each DETA batch undergoes HPLC analysis to verify purity, FTIR spectroscopy for structural confirmation, and moisture content testing to ensure stability. Every shipment includes a detailed Certificate of Analysis (COA) with actual test results, not generic specifications. With a production capacity of 500 metric tons monthly, we maintain 45-day lead times even during peak demand. Our 30-day return policy for non-conforming products—supported by third-party lab verification—provides additional assurance that your investment is protected.
Certificate of Analysis & Documentation
Every order of Diethylenetriamine (CAS 111-40-0) includes a batch-specific COA detailing purity, moisture content, and impurity profiles, along with a current MSDS compliant with REACH and OSHA standards. For critical applications, we provide full HPLC chromatograms and NMR spectra upon request, enabling direct comparison with your internal quality benchmarks. Historical batch data can be accessed via our customer portal using your order reference number.
Storage & Handling
- Store in a cool, dry, well-ventilated area, sealed and away from direct sunlight.
- Keep away from incompatible materials, food and feed sources.
- Handle with appropriate personal protective equipment (gloves, goggles, lab coat).
- Follow good industrial hygiene practices. Avoid inhalation and skin contact.
- Refer to MSDS for detailed storage and safety instructions.
How to Place Your Order
Initiate your purchase by submitting an inquiry through our platform, specifying required quantities and packaging preferences (plastic or steel drums). We’ll provide a formal quotation within 24 hours, including technical data sheets for review. For first-time customers, sample requests are welcome to validate compatibility with your processes. Once specifications are confirmed, standard orders ship within 5-7 business days, with tracking information provided for full supply chain visibility.
Frequently Asked Questions
Q: What is the shelf life of your Diethylenetriamine?
A: When stored in unopened original packaging under recommended conditions, our DETA maintains stability for 12 months from the date of manufacture.
Q: Can this product be used in food or pharmaceutical applications?
A: No, this product is strictly for industrial and laboratory research use only, as stated in our disclaimer.
Q: What documentation is provided with each shipment?
A: Each order includes a batch-specific COA, MSDS, and shipping documents. Additional testing reports are available upon request.
Q: Do you offer custom packaging options?
A: Yes, we can provide packaging in 200L plastic drums or 1000L IBC tanks based on your volume requirements.
Q: How is the product purity verified?
A: Purity is determined via HPLC analysis, with results documented in the COA. We use calibrated equipment traceable to international standards.